Electrostatic discharge (ESD) events are important indicators of excessive charge accumulation in environments where electrostatic charging is detrimental to manufacturing processes in the semiconductor or LCD industries.
Trek’s Model 900A is a diagnostic tool used to identify incidents or verify suspected areas of ESD activity. An ESD sensitive antenna on the unit can be positioned in ESD sensitive environments to detect problem areas of electrostatic discharges.
Trek’s Model 900A ESD Event Detector alerts and displays information concerning electrostatic discharges. Upon an ESD event detection, an audible buzzer automatically sounds for two seconds (or it can be switched OFF) while five (5) color coded LEDs visually depict the relative intensity level of the event.
Resetting the unit is either performed automatically or manually by the use of a front panel selector switch. The unit can be powered 5 to 7 hours from batteries or a power cube can be used for continuous AC line operation.
Trek’s Model 900 ESD Event Detector is CE compliant.
Detection levels:
Five (5) LEDs indicate the relative level of the ESD event
1st Level: Yellow
2nd Level: Yellow
3rd Level: Yellow
4th Level: Red
5th Level: Red
Reset Button
Clears all previous measurements.
External Monitor Connection
Allows remote monitoring for ESD events.
Auto Reset Switch
When switched ON, the Model 900A will automatically reset itself in two (2) seconds after an ESD event detection.
Power Indicator
A red LED is illuminated when the power is ON.
Power Requirements
Four AA Alkaline 1.5 V batteries provide 7 hours of operation. Four AA Ni-H 1.5 V batteries provide 5 hours of operation. An universal power adapter can be used for continuous AC line operation.
Dimensions
190 mm H (with antenna) x 83 mm W x 48 mm D
[7.5" H (with antenna) x
3.25" W x 1.9" D].
Weight
500 grams [1.1 lb] with batteries.
All specifications are subject to change.