Celebrating 40 Years of Innovation: 1968-2008

Products: High Voltage Power Amplifiers

Trek Model 603 Power Amplifier/Piezo Driver

Now equipped with SHV type high-voltage output connectors.

The Trek Model 603 is a DC-stable, Power Amplifier/Piezo Driver designed to provide precise control of output voltages in the ranges of 0 to ±125 V, 0 to -250 V, or 0 to +250 V DC or peak AC. The output current capability is 0 to ±40 mA DC or 0 to ±80 mA peak AC for all voltage ranges. The Model 603 features an all solid-state design for high slew rate, wide bandwidth, and low-noise operation. The four-quadrant, active output stage sinks or sources current into reactive or resistive loads throughout the output voltage range. This is essential for achieving the accurate output response and high slew rates demanded by reactive loads. Industrial applications using the Model 603 include driving piezoelectric actuators, modulating electrooptics, and electrostatic deflection.

The Model 603 is protected against overvoltage and overcurrent conditions generated by active loads or by output short circuits to ground. Precision voltage and current monitors provide low-voltage representations of the high-voltage output and load current for monitoring purposes or for use as feedback signals in a closed-loop system. The Digital Enable feature provides a connection for a remote device to turn ON and OFF the high-voltage output of the instrument. This makes the Model 603 suitable for automated or computer controlled systems.

The Dynamics Adjust feature can be used to optimize the AC response of the output signal. The Model 603 operates as a noninverting amplifier with a fixed gain. The input gain can be programmed for 25 V/V or 50 V/V. Consult the factory for information on reprogramming the factory set output configuration.

The Model 603 comes from the factory with settings for an output voltage of ±125 V DC or peak AC and a signal gain ratio of 50 V/V. The Model 603 is available in single or dual channel configurations.

back to top

AMPLIFIER INPUT & Output

  • Output Voltage Range
    Factory set for 0 to ±125 V DC or peak AC. Other available output voltage ranges are 0 to -250 V and 0 to +250 V DC or peak AC. This setting is customer specified. Contact TREK, INC. for more information.
  • Output Current Range
    (all output voltage ranges)
    0 to ±40 mA DC.
    0 to ±80 mA peak AC, for less than 1 ms.
  • Input Voltage Range
    0 to ±10 V DC or peak AC, noninverting.
  • Input Impedance
    10 kohm, nominal.

back to top

PERFORMANCE

  • DC Voltage Gain
    Factory set for 50 V/V. A gain of 25 V/V is available. This setting is customer specified. Contact TREK, INC. for more information.
  • DC Voltage Gain Accuracy
    Better than 0.1% of full scale.
  • Offset Voltage
    Less than 500 mV.
  • Output Noise
    Less than 20 mV rms (measured using the true rms feature of the Hewlett Packard Model 34401A digital multimeter).
  • Slew Rate (10% to 90%, typical)
    Greater than 100 V/µs.
  • Large Signal Bandwidth (5% distortion )
    DC to 150 kHz.
  • Settling Time to 1%
    Less than 5 µs for a 100 V step.
  • Stability
    • Drift with Time
      Less than100 ppm/hr, noncumulative.
    • Drift with Temperature
      Less than 25 ppm/°C.

back to top

PRODUCT FEATURES

  • The Model 603 can have up to two (2) independent amplifier channels in one enclosure. The following features are specific to each amplifier channel.
  • Output Voltage Configurations
    Factory set for 0 to ±125 V DC or peak AC. Other available output voltage ranges are 0 to -250 V, or 0 to +250 V DC or peak AC. This setting is customer specified. Contact TREK, INC. for more information.
  • Load Switch
    The Model 603 has a slide switch to select between high capacitive loads (more than 150 pF) or low capacitive loads (less than 150 pF).
  • Gain Configurations
    The gain of the Model 603 is factory set for 50 V/V. A voltage gain of 25 V/V is available. This setting is customer specified. Contact TREK, INC. for more information.
  • Dynamics Adjust
    A graduated one-turn panel potentiometer is used to optimize the AC response of the Model 603.
  • Digital Enable
    An input providing a connection for a TTL compatible signal to turn on and off the high-voltage output. A TTL high (or open) turns off the high-voltage output. A TTL low turns on the high-voltage output.
  • Voltage Monitor
    A buffered output providing a low-voltage replica of the high-voltage output.
    • Scale
      1/25th of the high-voltage output.
    • DC Accuracy
      Better than 0.1% of full scale.
    • Offset Voltage
      Less than 5 mV.
    • Output Noise
      Less than 5 mV rms (measured using the true rms feature of the Hewlett Packard Model 34401A digital multimeter).
    • Output Impedance
      Less than 0.1 ohm.
  • Current Monitor
    A buffered output providing a low-voltage representation of the load current.
    • Scale
      0.1 V/mA.
    • DC Accuracy
      Better than 1% of full scale.
    • Offset Voltage
      Less than 10 mV.
    • Output Noise
      Less than 10 mV (measured using the true rms feature of the Hewlett Packard Model 34401A digital multimeter).
    • Output Impedance
      Less than 0.1 ohm.

back to top

GENERAL

  • Dimensions
    • Single Channel Instrument
      222.3 mm W x 108 mm H x 381 mm D
      (8.75" W x 4.25" H x 15" D).
    • Dual Channel Instrument
      433.8 mm W x 108 mm H x 381 mm D
      (17.08" W x 4.25" H x 15" D).
  • Weight
    • Single Channel Instrument
      4.3 kg (9.4 lb).
    • Dual Channel Instrument
      8.6 kg (18.8 lb).
  • High-Voltage Output Connector
    SHV high-voltage connector.
  • Amplifier Input
    BNC coaxial connector.
  • Voltage Monitor
    BNC coaxial connector.
  • Current Monitor
    BNC coaxial connector.
  • Digital Enable Connector
    BNC coaxial connector.
  • Power Receptacle
    Standard three-prong power connector with an integral fuse holder.
  • Power Requirements
    • Line Voltage
      Factory set for one of two ranges: 90 to 127 V AC or 180 to 250 V AC, at 48 to 63 Hz. (This setting is customer specified. Contact TREK, INC. for more information.)
    • Power Consumption
      125 VA, maximum.
  • Operating Conditions
    • Temperature
      0 °C to 40 °C.
    • Relative Humidity
      To 85%, noncondensing.

back to top

ACCESSORIES SUPPLIED

Operator’s manual, SHV high-voltage mating connector for each amplifier channel, line cord.

back to top

CERTIFICATION

TREK, INC. certifies that each Model 603 is tested and calibrated to specifications using measurement equipment traceable to the National Institute of Standards and Technologyor traceable to consensus standards. A Certificate of Calibration accompanies each instrument when it is shipped from the factory.

Low Voltage Safety Compliance (EN 61010-1)

Installation Category
CAT II: Local-level mains, appliances, portable equipment.

Pollution Category

Degree 1: Operate in environments where no pollution occurs or only dry, nonconductive pollution occurs.

All specifications are with no load unless otherwise noted.
All specifications are subject to change.

back to top