Trek Model 541A electrostatic voltmeters are microprocessor based voltmeters which are ideally suited to monitor critical operations associated with semiconductor, LCD, electronic assembly, and other processes where static charge accumulation poses a threat to production yields or product quality.
The Model 541A voltmeters utilize a miniature electrostatic field chopper probe which can be remotely located and easily positioned within process equipment to provide highly accurate, noncontacting, DC stable, spacing independent, voltage measurements in either ionized or non-ionized environments.
A twenty by four (20 x 4) alphanumeric LCD screen displays the present measured voltage, the positive peak voltage value, the negative peak voltage value, and additional menu information. Two specific voltage detection ranges are available. The Model 541A-1 has a voltage measurement range of 0 to ±1 kV. The Model 541A-2 has a measurement range of 0 to ±100 V. Both instruments have exceptional 1% accuracy and 0.1% resolution.
The Model 541A series includes independently programmable plus (+) and minus (-) voltage threshold/alarm limits to provide audible, visual, and external warning signals. Audible and visible alarms indicate the detection of programmed surface voltage limits. A relay contact output changes state when alarm thresholds are met or exceeded. This signal can be connected to a process controlling device or other equipment to monitor a particular environment.
A voltage output monitor and the 4-20 mA current loop output can provide additional signal interfacing to facility monitoring equipment. Either an USB or RS-232 serial port can provide computer based control and monitoring.
The walking test adapter kit [CN 1K037 ] for the Model 541A allows analysis of charge levels accumulated on the human body per compliance with ANSI/ESD STM 97.2. and IEC Standard 61340-4-5. (click for picture)
Speed of Response (10% to 90%)
Model 541A-1
Less than 50 ms for a 1 kV step.
Model 541A-2
Less than 50 ms for a 100 V step.
Accuracy
1% of full scale
Alarm Output (Digital Alarm)
The alarm output is a logic-level output indicating the alarm status of the Model 541A. A TTL low (0 to 0.8 volts) signals an alarm condition. A TTL high (2.5 to 5.0 volts) indicates a normal condition.
Visual Alarms
LED's on front panel light when alarm thresholds are reached.
Audible Alarms (ON/OFF programmable)
A pulsating or continuous tone (selectable) is sounded when the programmed voltage limit is detected. The (+) and (-) alarms have different tone rates for the pulsed tone selection.
Alarm Relay Output
Form C relay contact with barrier strip terminals. Contacts will change state when voltage thresholds are met or exceeded. The NO (normally open) contact will become closed and the NC (normally closed) contact will become open.
Monitor Output
Model 541A-1
The voltage output at this connector is 1/100th of the measured voltage.
Model 541A-2
The voltage output at this connector is 1/10th of the measured voltage.
Output Noise
Less than 30 mV rms (measured using the true rms feature of the Hewlett Packard Model 34401A digital voltmeter).
Output Impedance
47 ohms.
ESVM ZERO
Control to produce zero volts when probe is coupled to a known zero source.
Reset
Resets the alarms (manual mode) and the Peak Hold display to zero.
Current Output
Provides a current of 4-20 mA that represents -1 kV to +1 kV (Model 541A-1) or -100 V to +100 V (Model 541A-2).
Serial Port
RS-232 controls functions and acquires sensor data through standard computer serial port.
MENU Buttons
Used for selecting and programming menu options. These buttons used to set alarm threshold voltages, alarm conditions, and alarm reset type.
Miniature electrostatic field chopper probe. End viewing and side viewing probes are available.
541P-S Probe
Side view, square body with 3 meters cable.
541PR-E Probe
End view, round body with 3 meters cable.
541PR-S Probe
Side view, round body with 3 meters cable.
Weight
0.77 kg (1.7 lb).
Power
15 V DC ±20%, 800 mA, power buss or AC/DC adapter with a 2.1 mm DC plug.
Operating Conditions
Temperature
15 °C to 35 °C.
Relative Humidity
5% to 85%, noncondensing.
Power ON/OFF
Rear panel switch.
Ground Receptacle
Banana jack.