Trek's Charge-to-Mass Ratio System (Model 210HS-3) is a portable Q/m analyzer which provides repeatable high accuracy toner charge measurements. This unit can be used directly on the production line as well as in the laboratory and employs unique technology to avoid measurement errors that can occur with other "blow-off" systems.
Trek offers a unique, small, and portable Q/m analyzer which utilizes the “draw-off” toner transfer method to yield repeatable high accuracy toner charge measurements. The Trek Model 210HS-3 Charge-to-Mass Ratio (Q/m) Test System* is used to quickly and accurately determine the charge-to-mass ratio characteristics of both single and dual component electrophotographic toners and other charged particulates. Interchangeable mesh filters accommodate various sizes of charged particles. The system is highly portable for use directly on the production line as well as in the laboratory.
The Trek Model 210HS-3 system employs a unique specimen separation and transfer technique which avoids the creation of measurement errors due to the undesired additional charging of the toner as caused by the rapid air movement associated with "blow-off" type measurement systems.
The Trek Model 210HS-3 is configured as a separate main indicator unit, a plug-in sample cell unit, and a plug-in absorption nozzle unit to allow for different configurations in response to various user applications. A two position switch selects pump strength for normal or high application needs, such as for measuring charge on single component toners (when stronger suction is required).
* Measuring toner mass requires the use of a weigh scale which is not included in the Charge-to-Mass Ratio Test System.
Front Panel Features
Pump Selection Switch
Selects either Normal pressure setting or High pressure setting.
Air Connector
A connector for connection of the air hose of the Absorption Nozzle Unit.
Reset 1 Switch
A switch to reset the coulombmeter for the Absorption Nozzle Unit to zero.
Reset 2 Switch
A switch to reset the coulombmeter for the Sample Cell Case to zero.
Display 1
A display to indicate the charge transfer to the Faraday cage in the
Absorption Nozzle Unit.
Display 2
A display to indicate the charge transfer from the Faraday cage in
the Sample Cell Case.
Rear Panel Featues
Output 2
A voltage output monitor which indicates the charge transfer from
the Faraday cage in the Sample Cell Case.
Scale Factor
1 V/uC.
Accuracy
Better than ±2% of full scale.
Air Outlet
Exit path for air.
Ground Connector
Threaded ground screw.
TREK, INC. certifies that every Model 210HS-3 Q/m Test system is tested and calibrated to specifications using measurement equipment traceable to the National Institute of Standards and Technology or traceable to consensus standards.
RoHS compliant (EU). CE compliant.
All specifications are subject to change.